Rumex Baltics
+371 67 148 083
9:00 - 18:00
Callback
Robezu 46, Riga, Latvia
Products
  • Ophthalmological Lasers
    Ophthalmological Lasers
  • Ophthalmic Diagnostics
    Ophthalmic Diagnostics
    • Autorefractometry
    • Corneal Biomechanics Analyzers
    • Myopia management
    • Non-Contact Tonometry
    • Ophthalmologist's workplace
    • Ophthalmoscopes
    • Perimetry
    • Projectors
    • Refraction
    • Slit Lamps
    • Tomography
    • Topography
    • Visual Test Equipment
    • More
  • Surgical Microscopes
    Surgical Microscopes
    • Biom
    • Microsurgery
    • Ophthalmology
  • Phaco Vitrectomy system
    Phaco Vitrectomy system
    • Consumables
    • Phaco Vitrectomy system
  • Ophthalmic lenses for diagnostics and surgery
    Ophthalmic lenses for diagnostics and surgery
    • Direct Fundus Lenses
    • Disposable Lenses
    • Indirect BIO Lenses
    • Indirect Slit Lamp Lenses
    • Wide Angle Contact Lenses
  • Cannulas
    Cannulas
  • Dry eye products
    Dry eye products
    • PAINLESS PLUG
    • PRELOADED PUNCTAL PLUGS
  • Epiphora products
    Epiphora products
  • Eye Spears & Points
    Eye Spears & Points
  • Eyelid repair products
    Eyelid repair products
  • IOLs
    IOLs
    • Rayner Intraocular Lenses Limited, UK
    • Rumex International Ltd
  • IRIS Retractors
    IRIS Retractors
  • Ophthalmic knives
    Ophthalmic knives
  • Ophthalmic Suture
    Ophthalmic Suture
  • Orbital implants
    Orbital implants
  • OVDs
    OVDs
    • Rayner Intraocular Lenses Limited, UK
    • Rumex International Ltd
  • Precivia
    Precivia
  • Silicon bands, sponges and sleeves
    Silicon bands, sponges and sleeves
  • Silicone Oil
    Silicone Oil
  • Sterilization and disinfection
    Sterilization and disinfection
    • Cassette autoclaves Statim
  • Ophthalmic Surgical Instruments
    Ophthalmic Surgical Instruments
Certificates
Company
  • Partners
Service
Contacts
    Rumex Baltics
    Products
    • Ophthalmological Lasers
      Ophthalmological Lasers
    • Ophthalmic Diagnostics
      Ophthalmic Diagnostics
      • Autorefractometry
      • Corneal Biomechanics Analyzers
      • Myopia management
      • Non-Contact Tonometry
      • Ophthalmologist's workplace
      • Ophthalmoscopes
      • Perimetry
      • Projectors
      • Refraction
      • Slit Lamps
      • Tomography
      • Topography
      • Visual Test Equipment
      • More
    • Surgical Microscopes
      Surgical Microscopes
      • Biom
      • Microsurgery
      • Ophthalmology
    • Phaco Vitrectomy system
      Phaco Vitrectomy system
      • Consumables
      • Phaco Vitrectomy system
    • Ophthalmic lenses for diagnostics and surgery
      Ophthalmic lenses for diagnostics and surgery
      • Direct Fundus Lenses
      • Disposable Lenses
      • Indirect BIO Lenses
      • Indirect Slit Lamp Lenses
      • Wide Angle Contact Lenses
    • Cannulas
      Cannulas
    • Dry eye products
      Dry eye products
      • PAINLESS PLUG
      • PRELOADED PUNCTAL PLUGS
    • Epiphora products
      Epiphora products
    • Eye Spears & Points
      Eye Spears & Points
    • Eyelid repair products
      Eyelid repair products
    • IOLs
      IOLs
      • Rayner Intraocular Lenses Limited, UK
      • Rumex International Ltd
    • IRIS Retractors
      IRIS Retractors
    • Ophthalmic knives
      Ophthalmic knives
    • Ophthalmic Suture
      Ophthalmic Suture
    • Orbital implants
      Orbital implants
    • OVDs
      OVDs
      • Rayner Intraocular Lenses Limited, UK
      • Rumex International Ltd
    • Precivia
      Precivia
    • Silicon bands, sponges and sleeves
      Silicon bands, sponges and sleeves
    • Silicone Oil
      Silicone Oil
    • Sterilization and disinfection
      Sterilization and disinfection
      • Cassette autoclaves Statim
    • Ophthalmic Surgical Instruments
      Ophthalmic Surgical Instruments
    Certificates
    Company
    • Partners
    Service
    Contacts
      Rumex Baltics
      EN
      LV LT EE
      • Products
        • Назад
        • Products
        • Ophthalmological Lasers
        • Ophthalmic Diagnostics
          • Назад
          • Ophthalmic Diagnostics
          • Autorefractometry
          • Corneal Biomechanics Analyzers
          • Myopia management
          • Non-Contact Tonometry
          • Ophthalmologist's workplace
          • Ophthalmoscopes
          • Perimetry
          • Projectors
          • Refraction
          • Slit Lamps
          • Tomography
          • Topography
          • Visual Test Equipment
        • Surgical Microscopes
          • Назад
          • Surgical Microscopes
          • Biom
          • Microsurgery
          • Ophthalmology
        • Phaco Vitrectomy system
          • Назад
          • Phaco Vitrectomy system
          • Consumables
          • Phaco Vitrectomy system
        • Ophthalmic lenses for diagnostics and surgery
          • Назад
          • Ophthalmic lenses for diagnostics and surgery
          • Direct Fundus Lenses
          • Disposable Lenses
          • Indirect BIO Lenses
          • Indirect Slit Lamp Lenses
          • Wide Angle Contact Lenses
        • Cannulas
        • Dry eye products
          • Назад
          • Dry eye products
          • PAINLESS PLUG
          • PRELOADED PUNCTAL PLUGS
        • Epiphora products
        • Eye Spears & Points
        • Eyelid repair products
        • IOLs
          • Назад
          • IOLs
          • Rayner Intraocular Lenses Limited, UK
          • Rumex International Ltd
        • IRIS Retractors
        • Ophthalmic knives
        • Ophthalmic Suture
        • Orbital implants
        • OVDs
          • Назад
          • OVDs
          • Rayner Intraocular Lenses Limited, UK
          • Rumex International Ltd
        • Precivia
        • Silicon bands, sponges and sleeves
        • Silicone Oil
        • Sterilization and disinfection
          • Назад
          • Sterilization and disinfection
          • Cassette autoclaves Statim
        • Ophthalmic Surgical Instruments
      • Certificates
      • Company
        • Назад
        • Company
        • Partners
      • Service
      • Contacts
      • +371 67 148 083
      Robezu 46, Riga, Latvia
      info@rumexbaltics.eu

      RayOne Aspheric

      • Main
      • Products
      • IOLs
      • Rayner Intraocular Lenses Limited, UK
      • RayOne Aspheric
      New
      • RayOne Aspheric
      • RayOne Aspheric
      • RayOne Aspheric
      • RayOne Aspheric
      • RayOne Aspheric
      • RayOne Aspheric
      • RayOne Aspheric
      • RayOne Aspheric
      • RayOne Aspheric
      • RayOne Aspheric
      • RayOne Aspheric
      • RayOne Aspheric
      Video
      Video
      Rayner Intraocular Lenses Limited, UK
      Rayner Intraocular Lenses Limited, UK

      Fully preloaded IOL injection system, designed to deliver without compromise. Unique patented Lock & Roll technology and MICS lens as part of the same design process; this combination has resulted in the smallest fully preloaded injector available (1.65 mm nozzle). RayOne Aspheric is an enhanced version of the tried-and-tested C-flex and Superflex platform, combined into a single 6 mm optic design.

      More
      Ask a question
      • Description
      • Characteristics
      • FAQ
      Description

      Fully preloaded IOL injection system, designed to deliver without compromise. Unique patented Lock & Roll technology and MICS lens as part of the same design process; this combination has resulted in the smallest fully preloaded injector available (1.65 mm nozzle). RayOne Aspheric is an enhanced version of the tried-and-tested C-flex and Superflex platform, combined into a single 6 mm optic design.

      Aberration-neutral technology for optimal visual quality and functional visual acuity in all light conditions.

      RayOne Aspheric is designed with an aspheric anterior surface that creates no spherical aberration.

      Studies have demonstrated that aberration-neutral technology:

      • Offers improved contrast sensitivity compared with spherical IOLs
      • Provides better low light level visual acuity than spherical IOLs
      • Can offer more depth of field than aberration-negative IOLs by retention of the patient’s natural level of corneal spherical aberration6
      • Are less susceptible to the effects of decentration than aberration-negative IOLs
      • Twice as many patients* preferred the aberration-neutral IOL than aberration-negative
      • Three times fewer reports of visual disturbances with the aberration-neutral IOL than aberration-negative

      Advantages:

      • Designed to deliver without compromise
      • Aberration-neutral technology for optimal visual quality and functional visual acuity in all light conditions. RayOne Aspheric is designed with an aspheric anterior surface that creates no spherical aberration.
      • Reducing dysphotopsia by design:

        - Rayner’s enhanced square edge technology shows no general increase in glare from previous models without a square edge

        - Low refractive index (1.46)

      • 360° Optimised Barrier to reduce PCO:

        Rayner’s 360° Amon-Apple enhanced square edge creates an optimum barrier to reduce epithelial cell migration including at the haptic-optic junction. Extremely low Nd: YAG capsulotomy rates, comparable with hydrophobic acrylic lenses with square-edge optics.

      • Vacuole free material for a glistening free IOL

        - Single piece IOL created from a homogeneous material free of microvacuoles

        - Compressible material for delivery through a micro incision

        - Excellent handling characteristics with controlled unfolding within the capsular bag

        - Low silicone oil adherence

        - Excellent uveal biocompatibility

        - Hydrophilic acrylic material with low inflammatory response

      • RayOne Aspheric with patented Lock & Roll technology for a smoother, more consistent rolling and delivery of the lens via micro incision
      • RayOne Aspheric enhanced 6 mm optic

        - Amon-Apple enhanced square edge for minimal PCO 1.7% at 24 months

        - Zero glistenings

        - Based on proven haptic technology for excellent stability

      • Anti-vaulting haptic technology provides excellent fixation in the capsular bag:

        -Superb centration – Average offset of only 0.08 mm 3 to 6 months after surgery

        -Excellent rotational and torsional stability – 1.83° mean IOL rotation 3 to 6 months after surgery

      • One solution for all your patients:

        -Largest fully preloaded power range on the market

        -Easy to use and efficient IOL delivery time

      Characteristics

      Description:

      Fully preloaded IOL, hydrophilic, aspherical, monofocal, for 2.2 mm incision.

      Material Single piece Rayacryl hydrophilic acrylic
      Water Content 26% in equilibrium
      UV Protection Benzophenone UV absorbing agent
      UV Light Transmission UV 10% cut-off is 380 nm
      Refractive Index 1.46
      ABBE 56
      Overall Diameter 12.50 mm
      Optic Diameter 6.00 mm
      Optic Shape Biconvex (positive powers), Biconcave (negative powers)
      Asphericity Anterior aspheric surface with aberration-neutral technology
      Optic Edge Design Amon-Apple 360° enhanced square edge
      Haptic Angulation 0°, uniplanar
      Haptic Style Closed loop with Anti-Vaulting Haptic (AVH) technology
      Power Range

      -10.0 D to +7.0 D (1.0 D increments, inc. plano)

      +8.0 D to +30.0 D (0.5 D increments)

      +31.0 D to +34.0 D (1.0 D increments)

      Delivery System Type Fully preloaded IOL injection system
      Incision Size Sub 2.2 mm

      FAQ

      General issues

      How to order a service?
      Call our manager at +371 29476657 or leave a request for the service in one of the forms on the website and you will definitely be called back to clarify the order.
      Contacts

      Share
      Back to list
      • Ophthalmological Lasers
      • Ophthalmic Diagnostics
      • Surgical Microscopes
      • Phaco Vitrectomy system
      • Ophthalmic lenses for diagnostics and surgery
      • Cannulas
      • Dry eye products
      • Epiphora products
      • Eye Spears & Points
      • Eyelid repair products
      • IOLs
        • Rayner Intraocular Lenses Limited, UK
        • Rumex International Ltd
      • IRIS Retractors
      • Ophthalmic knives
      • Ophthalmic Suture
      • Orbital implants
      • OVDs
      • Precivia
      • Silicon bands, sponges and sleeves
      • Silicone Oil
      • Sterilization and disinfection
      • Ophthalmic Surgical Instruments
      Our experts will answer any question about the product
      Ask a question
      Optimal choice
      Optimal choice Low prices
      and a wide range of products
      Rumex is always glad to have active and mutually beneficial cooperation and looks forward to a long-term relationship.
      Company
      Partners
      Products
      Ophthalmological Lasers
      Ophthalmic Diagnostics
      Surgical Microscopes
      Phaco Vitrectomy system
      Ophthalmic lenses for diagnostics and surgery
      Cannulas
      Dry eye products
      Epiphora products
      Eye Spears & Points
      Eyelid repair products
      IOLs
      IRIS Retractors
      Ophthalmic knives
      Ophthalmic Suture
      Orbital implants
      OVDs
      Precivia
      Silicon bands, sponges and sleeves
      Silicone Oil
      Sterilization and disinfection
      Ophthalmic Surgical Instruments
      Service
      Certificates
      Contacts

      +371 67 148 083
      9:00 - 18:00
      Robezu 46, Riga, Latvia
      Ask a question
      rumex.eu
      rumexinternational.ltd.uk
      © 2022 All rights reserved. Privacy Poilcy
      ×
      This site uses Cookies in order to improve the functioning and personalize your stay on the site. By using this website, you agree to the use of Cookies
      More